Design Criteria
Requirements
The following load criteria are based on Chapter 16 of the 2012 Virginia Construction Code, and Chapter 3 of the 2012 Virginia Residential Code.

Load Criteria

Type

Amount

Ground snow load 25 PSF (pounds per square foot)
Wind speed 90 miles per hour three second gust
76 miles per hour fastest wind speed
Earthquake spectral response .16 at short periods
Residential seismic design category B
Weathering probability for concrete Severe
Termite infestation probability Moderate to heavy
Decay probability Moderate
Ice / water shield required Yes
Winter design temperature 15 degrees Fahrenheit
Air freezing index Less than or equal to 1,500 degrees Fahrenheit
Frost depth 24 inches
Mean annual temperature 50 degrees Fahrenheit